Lenze · Decentralised frequency inverter 8400 motec (AS-Interface option) · EDS84DMOTASI EN 5.0 - 02/2019 29
Commissioning
Initial switch-on
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
6.4 Initial switch-on
Establishing communication
To establish communication, the inverter drive must be supplied with mains voltage.
AS-i communication requires voltage supply of the communication unit.
If this is requirement is not met, the "CE04: MCI communication error" error message (error No.
01.0127.00002) is output. The error must be reset in the Inverter Drive, so that AS-i
communication can be established.
•The Voltage supply
( 24) via the AS-i bus cable serves to maintain the AS-i communication in
case of a main supply failure.
During mains connection, all parameters (codes) are read.
Addressing can be carried out automatically via the master, an external addressing unit or
manually via codes in the »Engineer«.
Addressing the AS-i slaves
( 27)