Process data transfer
Accessing process data / PDO mapping
40
Lenze · Decentralised frequency inverter 8400 motec (AS-Interface option) · EDS84DMOTASI EN 5.0 - 02/2019
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
8.1 Accessing process data / PDO mapping
Process data are transferred via the MCI/CAN interface.
The process data is accessed via the LP_Network_In and LP_Network_Out port blocks.
Up to 8 words (16 bits/word) per direction can be exchanged.
The port/function blocks of the process data objects (PDO) are interconnected via the Lenze
»Engineer«.
[8-1] External and internal data transfer between the bus system, inverter, and application
Software manual / »Engineer« online help for the Inverter Drive 8400 motec
Here you will find detailed information on the port/function block interconnection in
the »Engineer« and on the port blocks.