Parameter data transfer
CTT2: Block parameter transfer
50
Lenze · Decentralised frequency inverter 8400 motec (AS-Interface option) · EDS84DMOTASI EN 5.0 - 02/2019
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Response from slave to master has failed:
After the acyclic read request (index 0x12 (18)) has failed, the master sends error codes.
Then the read request from master to slave with the index 0x21 (33) is repeated.
The slave sends the parameter values in code C13214/1...16
again.
Byte Contents / value
0 CTT2: Code
•Index 0x92 (146): Acyclic read request is not OK.
Read exception list (index 0x21 (33))
1 CTT2: Standard error code
CTT2: Standard error codes
( 52)
2Error code (MSB)
3Error code
4Error code
5Error code (LSB)
CTT2: Acyclic device error codes
( 53)