Appendix
Code table
12
296
EDBCSXM064 EN 11.0
IMPORTANTPossible settingsCode
SelectionLenze/
{Appl.}
DesignationNo.
C0354 Alternative node address for
CAN_IN/CAN_OUT (CAN bus
interface X4)
201
1 CAN addr. 129 1 {1} 512 Address 2 CAN1_IN
2 CAN addr. 1 Address 2 CAN1_OUT
3 CAN addr. 257 Address 2 CAN2_IN
4 CAN addr. 258 Address 2 CAN2_OUT
5 CAN addr. 385 Address 2 CAN3_IN
6 CAN addr. 386 Address 2 CAN3_OUT
C0355 Identifier for CAN_IN/CAN_OUT
(CAN bus interface X4)
Read only
351
1 CAN Id 1 {1} 2047 Identifier CAN1_IN
2 CAN Id Identifier CAN1_OUT
3 CAN Id Identifier CAN2_IN
4 CAN Id Identifier CAN2_OUT
5 CAN Id Identifier CAN3_IN
6 CAN Id Identifier CAN3_OUT
C0356 CAN time settings for CAN bus
interface X4
204
1 CAN times 3000 0 {1 ms} 65000 CAN boot−up time:
Delay time after mains
connection for initialisation
through the master.
2 CAN times 0
CAN2...3_OUT cycle times:
Factor for the task time to send
process data telegram.
0 = event−controlled
transmission
3 CAN times 0
4 CAN times 20 Delay time for initial
transmission of the process data
objects 2 and 3 after the CAN bus
changed to "Operational"
C0357 Monitoring time for CAN1...3_IN
(CAN bus interface X4)
225
1 CE monit time 3000 1 {1 ms} 65000 CE1 monitoring time
2 CE monit time 3000 CE2 monitoring time
3 CE monit time 3000 CE3 monitoring time
C0358 Reset node 0
Make a reset node for the CAN
bus node.
206
0 No function
1 CAN reset
C0359 CAN state
CAN bus status (interface X4)
Read only
214
0 Operational
1 Pre−operational
2 Warning
3 Bus off
4 Stopped

Table of Contents

Other manuals for Lenze ECSEM Series