13 Parameter reference
13.1 Parameters of the communication module
114
Lenze · E84AYCEO communication module (EtherNet/IP™) · Communication Manual · DMS 3.0 EN · 10/2013 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C13848
C13849
C13850
Parameter | Name:
C13848 | Last Conflicted MAC ID
Data type: OCTET_STRING
Index: 10727 = 0x29E7
Display of the MAC address of the EtherNet/IP node with the last address conflict (ACD).
The data of the last conflict will only be saved in this code if ACD is active at the moment when the conflict occurs
(C13846
=1).
(Instance attribute 11 (RemoteMAC) in the TCP/IP Interface Object (245 / 0xF5)
( 141))
Read access Write access CINH PLC STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13849 | Last Conflicted IP Address
Data type: UNSIGNED_8
Index: 10726 = 0x29E6
Display of the MAC address of the EtherNet/IP node with the last address conflict (ACD).
The data of the last conflict will only be saved in this code if ACD is active at the moment when the conflict occurs
(C13846
=1).
Display range (min. value | unit | max. value)
0 255
Subcodes Info
C13849/1 Last conflicted IP address (most significant byte)
C13849/2 Last conflicted IP address
C13849/3 Last conflicted IP address
C13849/4 Last conflicted IP address (least significant byte)
Read access Write access CINH PLC STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13850 | All words to scanner
Data type: INTEGER_16
Index: 10725 = 0x29E5
Display of the I/O data words transferred from the communication module (adapter) to the scanner.
In the subcodes, all I/O data words transferred to the scanner are displayed. However, only the configured I/O data
words are valid.
Display range (min. value | unit | max. value)
-32768 32767
Subcodes Info
C13850/1
...
C13850/16
Read access Write access CINH PLC STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT