2 Safety instructions
2.2 Device and application-specific safety instructions
12
Lenze · E84AYCEO communication module (EtherNet/IP™) · Communication Manual · DMS 3.0 EN · 10/2013 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
2.2 Device and application-specific safety instructions
During operation, the communication module must be securely connected to the standard
device.
With external voltage supply, always use a separate power supply unit, safely separated to EN
61800-5-1 in every control cabinet (SELV/PELV).
Only use cables corresponding to the given specifications.
Ethernet cable specification
( 31)
2.3 Residual hazards
Protection of persons
If the Inverter Drives 8400 are used on a phase earthed mains with a rated mains voltage 400 V,
protection against accidental contact is not ensured without implementing external measures.
Protective insulation
( 17)
Device protection
The communication module contains electronic components which may be damaged or destroyed
by electrostatic discharge.
Installation
( 23)
Documentation for the standard device, host, system/machine
All the other measures prescribed in this documentation must also be implemented.
Observe the safety instructions and application notes contained in this manual.