Lenze · E84AYCEO communication module (EtherNet/IP™) · Communication Manual · DMS 3.0 EN · 10/2013 · TD17 97
12 Error messages
12.2 Possible causes and remedies
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
12.2 Possible causes and remedies
In this chapter, all EtherNet/IP error messages are listed in the numerical order of the error numbers.
Possible causes and remedies as well as responses to the error messages are described in detail.
EtherNet/IP: Exist. connect. to 8400 lost [0x01bc3100]
EtherNet/IP: Memory: No Access [0x01bc5531]
EtherNet/IP: Memory: Read Error [0x01bc5532]
EtherNet/IP: Memory: Write Error [0x01bc5533]
EtherNet/IP: Restart by Watchdogreset [0x01bc6010]
Response (Lenze setting printed in bold) Setting: not possible
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
• The communication module is being supplied with
external voltage but the Inverter Drive 8400 is not
being supplied with voltage.
• The communication module has not been correctly
connected to the Inverter Drive 8400.
• Supply the Inverter Drive 8400 with voltage.
• Securely connect the communication module to the
Inverter Drive 8400.
Response (Lenze setting printed in bold) Setting: not possible
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Access to memory was not possible. Send communication module together with a
description of the fault to Lenze.
Response (Lenze setting printed in bold) Setting: not possible
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Parameter could not be read. • Download application again (including module).
• Send communication module together with a
description of the fault to Lenze.
Response (Lenze setting printed in bold) Setting: not possible
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Parameter could not be written. • Download application again (including module).
• Send communication module together with a
description of the fault to Lenze.
Response (Lenze setting printed in bold) Setting: not possible
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Communication module is defective. Send communication module with error description to
Lenze.