3 Product description
3.3 Product features
14
Lenze · E84AYCEO communication module (EtherNet/IP™) · Communication Manual · DMS 3.0 EN · 10/2013 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
3.3 Product features
Interface module for the EtherNet/IP communication system, for attachment to the expansion
slots of Inverter Drives 8400
The communication module can either be supplied internally by the standard device or
externally by a separate voltage source.
The Inverter Drive 8400 is always an adapter device:
EtherNet/IP adapter with "Level 2" functionality
2-port interface with integrated switch functionality
Access to all Lenze parameters (configurable via TCP/IP using the Lenze »Engineer«)
Up to 3 TCP/IP socket connections for communication with the Lenze »Engineer«
Support of "IP Config Pending" (activation of changed IP configuration by "power off/on" or
"type 0 reset")
Support of the redundancy protocol DLR (Device Level Ring) as "beacon-based ring node"
Up to 16 I/O data words (32 bytes) are possible.
Further CIP features:
Max. 8 CIP connections
1 "exclusive owner" connection
I/O connection type: cyclic
•Minimum I/O cycle time: 4 ms
Support of multicast messages, UCMM, ACD, BOOTP/DHCP, VLAN tagging/DSCP