13 Parameter reference
13.1 Parameters of the communication module
116
Lenze · E84AYCEO communication module (EtherNet/IP™) · Communication Manual · DMS 3.0 EN · 10/2013 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C13858
C13861
Parameter | Name:
C13858 | Ethernet Port Statistics
Data type: UNSIGNED_32
Index: 10717 = 0x29DD
Display of statistical values for the data transfer via the Ethernet connections
Subcodes Info
C13858/1 Ethernet port X259: RX
C13858/2 Ethernet port X259: RX CRC error
C13858/3 Ethernet port X259: RX discarded
C13858/4 Ethernet port X259: TX
C13858/5 Ethernet port X259: TX discarded
C13858/6 Ethernet port X260: RX
C13858/7 Ethernet port X260: RX CRC error
C13858/8 Ethernet port X260: RX discarded
C13858/9 Ethernet port X260: TX
C13858/10 Ethernet port X260: TX discarded
Read access Write access CINH PLC STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13861 | CIP Module Status
Data type: UNSIGNED_16
Index: 10714 = 0x29DA
Display of the current CIP module status
(Instance attribute 8 (State) in the Identity Object (1 / 0x01)
( 126))
• The status is also indicated via the MS LED.
LED status displays
( 89)
Selection list (read only)
0 Nonexistent
1 Device Self Testing
2 Standby
3 Operational
4 Major Recoverable Fault
5 Major Unrecoverable Fault
Read access Write access CINH PLC STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT