6 Commissioning
6.4 Setting the IP configuration of the Inverter Drive 8400
44
Lenze · E84AYCEO communication module (EtherNet/IP™) · Communication Manual · DMS 3.0 EN · 10/2013 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
2. A double-click on a EtherNet/IP node opens the "Configure nodes" dialog window.
Here you can set the IP parameters.
3. Click on Transferred.
The IP configuration is transferred to the corresponding EtherNet/IP node.
The communication module carries out a stack reset.
•The IP parameters are written to codes C13000
(IP address), C13001 (subnet mask), and
C13002
(gateway address).
•Code C13005
(IP configuration reference) is set to ’0: Saved address’ to ensure that the
transferred address can be used.
Tip!
Check whether the configuration has been transferred successfully.
For this purpose, open the "Assign IP addresses" dialog window (see step 1) and click the
Find device button.