Technical data
3-4
L
MA9300PLC EN 1.4
3.4 Rated data
3.4.1 Types 9321 to 9325
Type EVS9321-EI EVS9322-EI EVS9323-EI EVS9324-EI EVS9325-EI
Order no. EVS9321-EI EVS9322-EI EVS9323-EI EVS9324-EI EVS9325-EI
Type EVS9321-CI EVS9322-CI EVS9323-CI EVS9324-CI EVS9325-CI
Order no. EVS9321-CI EVS9322-CI EVS9323-CI EVS9324-CI EVS9325-CI
Mains voltage V
r
[V] 320 V - 0 % ≤ V
r
≤ 528V+0%; 45Hz-0%... 65Hz+0%
Alternative DC supply V
DC
[V] 460 V - 0 % ≤ V
DC
≤ 740 V + 0 %
Mains current with mains filter
Mains current without mains filter
I
r
[A] 1.5
2.1
2.5
3.5
3.9
5.5
7.0
-
12.0
16.8
Ratings for operation at a mains: 3 AC / 400V / 50Hz/60Hz
Motor power (4-pole ASM)
P
r
[kW] 0.37 0.75 1.5 3.0 5.5
P
r
[hp] 0.5 1.0 2.0 4.0 7.5
Output power U, V, W (8kHz*) S
r8
[kVA] 1.0 1.7 2.7 4.8 9.0
Output power + U
DC
,-U
DC
2)
P
DC
[kW] 2.0 0.75 2.2 0.75 0
Output current (8 kHz*) I
r8
[A] 1.5 2.5 3.9 7.0 13.0
Output current (16 kHz*) I
r16
[A] 1.1 1.8 2.9 5.2 9.7
Max. output current (8 kHz*)
1)
I
max8
[A] 2.3 3.8 5.9 10.5 19.5
Max. output current (16 kHz*)
1)
I
max16
[A] 1.7 2.7 4.4 7.8 14.6
Max. standstill current (8 kHz*) I
08
[A] 2.3 3.8 5.9 10.5 19.5
Max. standstill current (16 kHz*) I
016
[A] 1.7 2.7 4.4 7.8 14.6
Ratings for operation at a mains: 3 AC / 480V / 50Hz/60Hz
Motor power (4-pole ASM)
P
r
[kW] 0.37 0.75 1.5 3.0 5.5
P
r
[hp] 0.5 1.0 2.0 4.0 7.5
Output power U, V, W (8kHz*) S
r8
[kVA] 1.2 2.1 3.2 5.8 10.8
Output power + U
DC
,-U
DC
2)
P
DC
[kW] 2.0 0.75 2.2 0.75 0
Output current (8 kHz*) I
r8
[A] 1.5 2.5 3.9 7.0 13.0
Output current (16 kHz*) I
r16
[A] 1.1 1.8 2.9 5.2 9.7
Max. output current (8 kHz*)
1)
I
max8
[A] 2.3 3.8 5.9 10.5 19.5
Max. output current (16 kHz*)
1)
I
max16
[A] 1.7 2.7 4.4 7.8 14.6
Max. standstill current (8 kHz*) I
08
[A] 2.3 3.8 5.9 10.5 19.5
Max. standstill current (16 kHz*) I
016
[A] 1.7 2.7 4.4 7.8 14.6
Motor voltage V
M
[V] 0-3× V
Mains
Power loss (operation with I
ratedx
) P
loss
[W] 100 110 140 200 260
Power derating [%/K]
[%/m]
40 °C < T
amb
< 55 °C: 2%/K (not UL approved)
1000 m amsl < h
≤ 4000 m amsl: 5%/1000m
Weight m[kg] 3.5 3.5 5.0 5.0 7.5
1)
The currents apply to a periodical load cycle with 1 minute overcurrent with the current mentioned
here and 2 minutes base load with 75% I
ratedx
2)
When operated under rated load, the controller can supply this power additionally.
*
Chopper frequency of the inverter (C0018)