f
M, U
U
AC
f
N
V Voltage U
AC
Mains voltage
f Frequency f
rated
Rated frequency
M Torque
VFCeco
The VFCeco mode has a special eect in the paral load operaonal range. Usually, three-
phase AC motors are supplied there with a higher magnesing current than required by the
operang condions. The VFCeco mode reduces the losses in the paral load operaonal
range so that savings up to 30 % are possible.
f
U
U
N
U
AC
f
N
f
max
VFCeco
V Voltage f Frequency
U
AC
Mains voltage f
rated
Rated frequency
U
rated
Rated voltage f
max
Max. frequency
Sensorless vector control (SLVC)
In vector control, an inverted voltage model is used for calculaon. The parameters are detec-
ted via a parameter idencaon. The inverter determines the angle between current and
voltage. This imposes a current on the motor.
Compared to the V/f characterisc control, the vector control serves to achieve improved
drive characteriscs thanks to:
higher torque throughout the enre speed range
higher speed accuracy and higher concentricity factor
higher eciency