Fusing data
Fusing data
Inverter i550-C0.37/400-3 i550-C0.55/400-3 i550-C0.75/400-3 i550-C1.1/400-3
Cable installaon in compliance
with
EN 60204-1
without mains choke
Circuit breaker
Characteriscs B
Max. rated current A 10 10 10 16
Fuse
Characteriscs gG/gL or gRL
Max. rated current A 10 10 10 16
with mains choke
Circuit breaker
Characteriscs B
Max. rated current A 10 10 10 16
Fuse
Characteriscs gG/gL or gRL
Max. rated current A 10 10 10 16
Earth-leakage circuit breaker
3-phase mains connecon ≥ 30 mA, type B
Fusing data
Inverter i550-C1.5/400-3 i550-C2.2/400-3
Cable installaon in compliance
with
EN 60204-1
without mains choke
Circuit breaker
Characteriscs B
Max. rated current A 16 16
Fuse
Characteriscs gG/gL or gRL
Max. rated current A 16 16
with mains choke
Circuit breaker
Characteriscs B
Max. rated current A 16 16
Fuse
Characteriscs gG/gL or gRL
Max. rated current A 16 16
Earth-leakage circuit breaker
3-phase mains connecon ≥ 30 mA, type B
Technical data
3-phase mains connecon 480 V
Fusing data
163