Funconal safety
DANGER!
Improper installaon of the safety engineering system can cause an uncontrolled starng
acon of the drives.
Possible consequences: Death or severe injuries
Safety engineering systems may only be installed and commissioned by qualied and skilled
personnel.
All control components (switches, relays, PLC, ...) must comply with the requirements of the
EN ISO 13849−1 and the EN ISO 13849−2.
Switches, relays with at least IP54 enclosure.
Control cabinet with at least IP54 enclosure.
It is essenal to use shields for the wiring.
It is essenal to use insulated wire end ferrules for wiring.
All safety relevant cables outside the control cabinet must be protected, e.g. by means of a
cable duct
Ensure that no short circuits can occur according to the specicaons of the
EN ISO 13849−2.
All further requirements and measures can be obtained from the EN ISO 13849−1 and the
EN ISO 13849−2.
If an external force acts upon the drive axes, addional brakes are required. Please observe
that hanging loads are subject to the force of gravity!
The user has to ensure that the inverter will only be used in its intended applicaon within
the specied environmental condions. This is the only way to comply with the declared
safety-related characteriscs.
DANGER!
Automac restart if the request of the safety funcon is deacvated.
Possible consequences: Death or severe injuries
You must provide external measures according to EN ISO 13849−1 which ensure that the
drive only restarts aer a conrmaon.
NOTICE
Excessively high humidity or condensaon
Malfuncon or destrucon of the safety component
Only commission the safety component when it has acclimased.
NOTICE
Overvoltage
Destrucon of the safety component
The maximum voltage (maximum rated) at the safety inputs is 30 V DC. The user must make
provisions to avoid that this voltage is exceeded.
Idencaon of the components
Safety components and the respecve terminals are yellow.
Informaon on electrical installaon
Funconal safety