Inverter load characteriscs
The inverter has two dierent load characteriscs: "Light Duty" and "Heavy Duty". The "Light
Duty" load characterisc allows for a higher output current with restricons regarding over-
load capacity, ambient temperature and switching frequency. This allows the motor required
for the applicaon to be driven by a less powerful inverter. Select the load characterisc
according to the applicaon.
Heavy Duty compared to Light Duty
The table compares both possible conguraons:
Heavy Duty Light duty
Characteriscs High dynamic requirements Low dynamic requirements
Typical applicaons Main tool drives, travelling drives, hoist drives,
winders, forming drives and conveyors
Pumps, fans, general horizontal materials handling technol-
ogy and line drives
Overload capacity 3 s/200 %, 60 s/150 %
see technical data
restricted
see technical data
Devices with Light Duty load characterisc: See ^ 137, ^ 182
Comply with all data for this load characterisc and the corresponding mains
voltage range. This comprises the informaon on the type of installaon as well
as the required fuses, cable cross-secons, mains chokes and lters.
Informaon on project planning
Project planning process
Overcurrent operaon
32