Safe mung (MUT)
(From standard device rm
ware V1.3, safety rmware V1.1 with parameter set version V1.1)
The “safe mung
” safety funcon may only be used during commissioning or
maintenance work.
It serves to move the motor even if the inverter is in a safety state.
The safe mung funcon deacvates selected safe inputs and all funcons of the safety bus.
The safe mung funcon can only be acvated via the LSPE (Lenze Safety Parameter Editor).
For this purpose, a special mung password must be entered.
Within a network, the safe mung funcon c
an always only be acvated for one inverter.
The safe mung funcon is maximally acve for 30 minutes. It can be interrupted or stopped
anyme.
Please note the following:
If the sa
fe mung funcon is stopped or interrupted by an error, the inverter
automacally changes to the monitored state.
All safety funcons that have been deacvated before become acve again.
DANGER!
Acvang the sa
fe mung funcon deacvates safety funcons!
This may result in severe injuries or death!
▶
Only authorized personnel is permied to acvate the safe mung funcon.
▶
One input must be parameterized as emergency stop. This input must not be deacvated by
safe mung.
Condions
In order to acv
ate the safe mung funcon, you need the following:
•
A PC with »Easy Starter« (1.16 or higher) or »PLC Designer« with LSPE (Lenze Safety
Parameter Editor).
•
A permanent communicaon link between LSPE and inverter.
If the connecon is interrupted during safe mung, safe mung is aborted immediately
with an error message. The inverter changes to the monitored operaon where all safety
funcons are acve again.
•
A valid parameter set that contains the sengs for safe mung:
•
The sources to be hidden. 0x213A
•
The mung password. 0x213B:001
Acvaon of the funcon
Acvate safe mung
1.Go to the »Easy Starter« and open the Safety parameter list tab.
2.Select safe mung.
3.Enter password.
4.Check informaon in the window and ensure that the correct device has been selected.
The opcal device detecon is acvated automacally. The blinking blue LED indicates the
inverter with acvated safe mung.
5.Start acvates the safe mung funcon.
The safe mung funcon is acve now.
Deacvaon of the funcon
Deacvate safe mung
1.Close deacvates the safe mung funcon for the input.
The safe mung funcon is inacve now.
Product extensions
Funconal sa
fety
Safety funcons
147