EasyManua.ls Logo

Lenze i950 - Supply Voltage Connection

Lenze i950
184 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
I95AE390F, I95AE411F
3
3
Supply voltage c
onnecon
An external 24 V supply voltage to X5:24E/GE is necessary for supplying the control
electronics.
If the control electronics are supplied independently of the AC grid of the inverter, the inverter
can also be congured when the AC grid is turned o. Communicaon via exisng networks
also remains available.
DANGER!
A common power supply unit for X107 and X5 removes the safe isolaon of the control card
from the mains potenal - even if a SELV/PELV power supply unit is used.
Possible consequences: Electric shock in the event of an error.
▶
Always supply X107 and X5 via separate SELV/PELV power supply units.
Informaon on electric