EasyManua.ls Logo

Lenze i950 - Terminal Data

Lenze i950
184 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Terminal data
X1 Specicaon Unit min. typ. max.
SIA, SIB LOW signal V -3 0 +5
HIGH signal V +15 +24 +30
Running me ms 10
Clear me ms 15 30
Input current mA 8 12
Input peak current mA 400
Input capacitance SIA
µF 5
Input capacitance SIB
Test pulse dur
aon ms 1
Test pulse interval ms 10
GS Reference potenal for SIA and SIB
Runme = St
art of rising edge at SIA, SIB unl internal HIGH signal is detected.
Switch-o me = Start of falling edge at SIA, SIB unl internal LOW signal is
detected.
Connecon descripon Basic Safety STO
Connecon X1
Connecon type Pluggable double spring terminal
Max. cable cross-secon mm² 1.5
Max. cable cross-secon AWG 16
Stripping length mm 9
Stripping length inch 0.35
Tightening torque Nm -
Tightening torque lbf∙in -
Required tool 0.4 x 2.5
Informaon on electric
al installaon
Funconal safety
Basic Safety - STO
65