Mounng
Shield mounng kit
Mot
or cable
If the shielding of the motor cable is centrally connected to an earthing busbar in the control
cabinet, no shielding is required.
For a direct connecon of the shielding of the motor cable to the inverter, the oponally
available accessories can be used consisng of shield sheet and xing clips or wire clamps.
From 22 kW onwards, the shield sheet is integrated.
Inverter Shield mounng kit
Order code Packaging unit Order code Packaging unit
Unit Unit
i950-C0.55/400-3
EZAMBHXM018/M
5x motor shield plate
5x xing clip
5x wir
e clamp (cable diameter 0.157 ...
0.591 in ( 4 ... 15 mm))
EZAMBHXM018/S
1x motor shield plate
1x xing clip
1x wire clamp (cable diameter 0.157 ...
0.591 in ( 4 ... 15 mm))
i950-C0.75/400-3
i950-C2.2/400-3
i950-C4.0/400-3
i950-C7.5/400-3
EZAMBHXM016/M
5x motor shield plate
5x xing clip
5x wire clamp (cable diameter 0.394 ...
0.787 in ( 10 ... 20 mm))
5x M4x12 screw
EZAMBHXM016/S
1x motor shield plate
1x xing clip
1x wire clamp (cable diameter 0.394 ...
0.787 in ( 10 ... 20 mm))
1x M4x12 screw
i950-C11/400-3
i950-C15/400-3
i950-C22/400-3 EZAMBHXM004/M 10x wire clamp (cable diameter 0.591 ...
1.102 in ( 15 ... 28 mm))
- -
i950-C30/400-3
EZAMBHXM004/M
10x wire clamp (cable diameter 0.591 ...
1.102 in ( 15 ... 28 mm))
EZAMBHXM005/M
10x wire clamp (cable diameter
0.787 ... 1.457 in ( 20 ... 37 mm))
i950-C45/400-3
i950-C55/400-3
EZAMBHXM004/M
10x wire clamp (cable diameter 0.591 ...
1.102 in ( 15 ... 28 mm))
EZAMBHXM005/M
10x wire clamp (cable diameter
0.787 ... 1.457 in ( 20 ... 37 mm))
i950-C75/400-3
i950-C90/400-3
- - - -
i950-C110/400-3
Accessories
Mounng
Shield mounng kit
166