3-phase mains c
onnecon 480 V
Rated data
Inverter i950-C0.55/400-3 i950-C0.75/400-3 i950-C2.2/400-3 i950-C4.0/400-3
Rated power kW 0.55 0.75 2.2 4
Rated power hp 0.75 1 3 5
Line voltage range 3/PE AC 340 V ... 528 V, 45 Hz ... 65 Hz
Output voltage 3 AC 0-480 V
Rated line current
Without choke A 2.1 2.8 6.5 10.5
With choke A 1.7 2.2 4.4 7.5
Apparent output power kVA 1.2 1.6 3.8 6.4
Rated output current
2 kHz A 1.6 2.1 4.8 8.2
4 kHz A 1.6 2.1 4.8 8.2
8 kHz A 1.6 2.1 4.8 6.2
16 kHz A 1.1 1.4 2.2 2.5
Power loss
2 kHz W 38 44 76 116
4 kHz W 39 46 80 122
8 kHz W 45 54 99 154
16 kHz W 45 54 99 154
For controller inhibit W 20 20 20 20
Overcurrent cycle 180 s
Max. output current A 2.4 3.2 7.2 12.3
Overload me s 60 60 60 60
Recovery me s 120 120 120 120
Max. output current during the
r
ecovery me
A 1.2 1.6 3.6 6.2
Overcurrent cycle 15 s
Max. output current A 3.2 4.2 9.6 16.4
Overload me s 3 3 3 3
Recovery me s 12 12 12 12
Max. output current during the
r
ecovery me
A 1.2 1.6 3.6 6.2
Cyclic line voltage switching 3 mes per minute
Brake chopper
Max. output current A 2 2 5.2 16.6
Min. brake resistance Ω 390 390 150 47
Max. shielded motor cable length
Category C2 (2 kHz, 4 kHz, 8
kHz)
m 20 20 20 20
Category C3 (2 kHz, 4 kHz, 8
kHz)
m 35 35 35 35
Without EMC category m 50 50 50 50
Weight kg 1.6 1.6 1.6 1.6
Weight lb 3.5 3.5 3.5 3.5
Technical data
3-phase mains c
onnecon 480 V
Rated data
79