Inverter i950-C7.5/400-3 i950-C11/400-3 i950-C15/400-3 i950-C22/400-3
Rated power kW 7.5 11 15 22
Rated power hp 10 15 20 30
Line voltage range 3/PE AC 340 V ... 528 V, 45 Hz ... 65 Hz
Output voltage 3 AC 0-480 V
Rated line current
Without choke A 16.6 23.7 - 47.4
With choke A 13.1 18.6 24 35.3
Apparent output power kVA 11 16 22 32
Rated output current
2 kHz A 14 21 27 40.4
4 kHz A 14 21 27 40.4
8 kHz A 14 21 19.8 40.4
16 kHz A 7.8 7.8 7.2 26.9
Power loss
2 kHz W 186 256 342 505
4 kHz W 197 272 363 536
8 kHz W 252 351 471 694
16 kHz W 252 351 471 694
For controller inhibit W 20 20 20 32
Overcurrent cycle 180 s
Max. output current A 21 31.5 40.5 61
Overload me s 60 60 60 60
Recovery me s 120 120 120 120
Max. output current during the
r
ecovery me
A 10.5 15.8 20.3 30
Overcurrent cycle 15 s
Max. output current A 28 42 54 81
Overload me s 3 3 3 3
Recovery me s 12 12 12 12
Max. output current during the
r
ecovery me
A 10.5 15.8 20.3 30
Cyclic line voltage switching 3 mes per minute
Brake chopper
Max. output current A 29 29 43 52
Min. brake resistance Ω 27 27 18 15
Max. shielded motor cable length
Category C2 (2 kHz, 4 kHz, 8
kHz)
m 20 20 20 20
Category C3 (2 kHz, 4 kHz, 8
kHz)
m 35 35 35 35
Without EMC category m 100 100 100 100
Weight kg 3.9 3.9 3.9 10.7
Weight lb 8.6 8.6 8.6 23.6
Technical data
3-phase mains c
onnecon 480 V
Rated data
80