Mains c
onnecon
The following should be considered for the mains connecon of inverters:
Single inverters are either directly connected to the AC system or via upstream lters. RFI
lters are already integrated in many inverters. Depending on the requirements, mains chokes
or mains lters can be used.
Inverter groups are connected to the DC system with the DC bus. For this purpose, the
inverters have to be provided with a connecon for the DC link, e. g. terminals +UG/-UG.
This enables the energy exchange in phases with operaon in generator and motor mode of
several drives in the network.
The DC system can be provided by power supply modules (AC/DC converters) or inverters with
a power reserve.
The technical data informs about the possible applicaons in the given groups. In the
dimensioning, data and further notes have to be observed.
The following examples contain the connecon opons for the variant Basic Safety - STO.
Informaon on electric
al installaon
Mains connecon
46