Codes
Diagnostics codes
10
78
EDS82ZAFPC010 EN 4.0
C1516: Display baud rate
Code Subcode Index
Possible settings
Data type
Lenze Selection
C1516 23059
d
=
5A13
h
0 [1] 9
FIX32
0: 12 Mbps
1: 6 Mbps
2: 3 Mbps
3: 1.5 Mbps
4: 500 kbps
5: 187.5 kbps
6: 93.75 kbps
7: 45.45 kbps
8: 19.2 kbps
9: 9.6 kbps
C1517: Display bus device address
Code Subcode Index
Possible settings
Data type
Lenze Selection
C1517 23058
d
=
5A12
h
3 [1] 126 FIX32
Display of the valid bus device address, which has been set via the DIP switches S1 ... S7 or
via code C1509.