Installation and commissioning
DIGIDRIVE
Variable speed drive
52
Réf. 3218 GB - 4.33 / d - 02.02
LEROY-SOMER
4.6 - Using a security code
4.6.1 - Locking the settings using a security code.
Access to modification of the parameter.
Action Display Comment
Power-up
Drive locked
Selection of parameter 25.
CAUTION:
It is not possible to access parameter 25
until 10 has been set to L2
(see procedure in section 4.3.3).
Enter the security code.
For example code 5.
CAUTION:
Code 0 is not permitted.
The security code is taken into account.
Parameter 25 returns to 0.
M
1x
M
1x
M
M
M
Return to parameter 10 to store the
security code.
M
Access to parameter setting of 10.
Select the value " LoC ".
Return to the initial drive status.
The security code is stored. Parameter
10 automatically returns to value L1.
Access to parameter-setting mode
Parameter 01 is displayed flashing.
1x
M
1x
M
1x
M
1x
M
1x
5x
M
1x
Parameters 01 to 10 can only be accessed
in read mode. To access the other parameters
(in read mode only), 10 must be set to L2.