Installation and commissioning
DIGIDRIVE
Variable speed drive
60
Réf. 3218 GB - 4.33 / d - 02.02
LEROY-SOMER
4.8 - Setting the level 2 parameters
4.8.1 - List of parameters 1
1
1
1
to 5
5
0
0
Glossary:
R - W: Read-write parameter.
RO: Read-only parameter.
CAUTION: The factory settings are given for a 50 Hz mains supply
Parameter Name Type Adjustment range
Factory
1
1
1
1
Preset frequency 1
R - W
±1000.0 Hz 0
1
1
2
2
Preset frequency 2
R - W
±1000.0 Hz 0
1
1
3
3
Preset frequency 3
R - W
±1000.0 Hz 0
1
1
4
4
Preset frequency 4
R - W
±1000.0 Hz 0
1
1
5
5
Jog operation frequency
R - W
0 to 400.0 Hz 1.5 Hz
1
1
6
6
Selection of the type of signal for
analogue input 2 (A2)
R - W
0-20, 20-0, 4-20,
20-4, 4-.20, 20-.4 (mA)
4-.20 mA
1
1
7
7
Selection of bi-directional mode
R - W
OFF or On OFF
1
1
8
8
Fault - 1
RO
0 to 189 (see section
1
1
9
9
Fault - 2
RO
0 to 189 (see section
2
2
0
0
Fault - 3
RO
0 to 189 (see section
2
2
1
1
Fault - 4
RO
0 to 189 (see section
2
2
2
2
Selection of load display
R - W
Ld, A Ld
2
2
3
3
Unit for displaying speed
R - W
Fr, SP, Cd Fr
2
2
4
4
Customer-defined unit scaling
R - W
0 to 99.99 1.00
2
2
5
5
Security code
R - W
0 to 9999 0
2
2
6
6
Enable FWD/REV key on the
keypad
R - W
OFF or On OFF
2
2
7
7
Keypad reference on
power-up
R - W
0, LASt, PrS1 0
2
2
8
8
Copy parameters
R - W
no, rEAD, Prog, Auto,
boot
no
2
2
9
9
Return to factory settings and brake
R - W
no, Eur, USA, br.Eu,
no
control br.US
3
3
0
0
Deceleration mode
R - W
0 to 2 1
3
3
1
1
Stop mode
R - W
0 to 3 1
3
3
2
2
Selection of dynamic U/f ratio
R - W
OFF or On OFF
3
3
3
3
Selection of flying restart
R - W
0 to 3 0
3
3
4
4
Control logic polarity
R - W
OFF or On On
3
3
5
5
Management of logic commands
R - W
0 to 3 0
3
3
6
6
Assignment of the analogue output
R - W
Fr, Ld, AdV Fr
3
3
7
7
Switching frequency
R - W
3, 6, 12 kHz 6 kHz
3
3
8
8
Selection of autocalibration
R - W
0 to 2 0
3
3
9
9
Motor rated frequency
R - W
0 to 1000.0 Hz 50.0 Hz
4
4
0
0
Number of motor poles
R - W
Auto, 2P, 4P, 6P, 8P Auto
4
4
1
1
Serial link mode
R - W
AnSI, Ct, FbUS AnSI
4
4
2
2
Serial link transmission speed
R - W
2.4 - 4.8 - 9.6 - 19.2 4.8
4
4
3
3
Serial link address
R - W
0 to 24.7 1.1
4
4
4
4
Software version
RO
1.00 to 99.99
4
4
5
5
Station address
R - W
0 to 255 0