Mounting
Leuze electronic MLC 520 31
Fig.6.10: Mounting directly on the machine table
WARNING
Impairment of the protective function due to reflections on the machine table!
Ä Make sure that reflections on the machine table are prevented reliably.
Ä After mounting and every day after that, check the detection capability of the safety sensor
in the entire protective field using a test rod (see chapter 9.3.1 "Checklist – periodically by
the operator").
6.3 Mounting accessories
6.3.1 Deflecting mirror for multiple-side guarding
For multiple-side guarding, redirecting the protective field with one or two deflecting mirrors is economical.
To do this, Leuze electronic supplies:
• The UM60 deflecting mirror for mounting on the machine in various lengths (see chapter 15 "Ordering
information and accessories")
• suitable BT-2UM60 swivel mounts
• UMC-1000-S2…UMC-1900-S2 deflecting mirror columns with spring-damped base for free-standing
floor mounting
The range is reduced by approx.10% per deflection. A laser alignment aid with red light laser is recom-
mended for the alignment of transmitter and receiver (see chapter 8.3 "Aligning of deflecting mirrors with
the laser alignment aid").
Ä Note that the distance between the transmitter and the first deflecting mirror cannot be larger than 3m.