Electrical connection
Leuze electronic MLC 520 34
7 Electrical connection
WARNING
Faulty electrical connection or improper function selection may result in serious injury!
Ä Only allow competent persons to perform the electrical connection.
Ä Make certain that the safety sensor is protected against overcurrent.
Ä For access guarding, activate the start/restart interlock and make certain that it cannot be
unlocked from within the danger zone.
Ä Select the functions so that the safety sensor can be used as intended (see chapter 2.1 "Ap-
proved purpose and foreseeable improper operation").
Ä Select the safety-relevant functions for the safety sensor (see chapter 4 "Functions").
Ä Always loop both safety-related switching outputs OSSD1 and OSSD2 into the work circuit
of the machine.
Ä Signal outputs must not be used for switching safety-relevant signals.
NOTICE
SELV/PELV
Ä Acc. to EN60204-1, the external power supply must demonstrate the ability to bridge short-
term mains failures of up to 20ms. The power supply unit must ensure safe mains separa-
tion (SELV/PELV) and a current reserve of at least 2A.
NOTICE
For special EMC stress, the use of shielded cables is recommended.
7.1 Pin assignment transmitter and receiver
7.1.1 MLC500 transmitter
MLC500 transmitters are equipped with a 5-pin M12 connector.
VIN1
1
RNG
4
VIN2
3
FE
5
-A1
MLCx00T
n.c.
2
Fig.7.1: Pin assignment and connection diagram transmitter
Tab.7.1: Pin assignment transmitter
Pin Core color (CB-M12-xx000E-5GF) Transmitter
1 Brown VIN1 - supply voltage
2 White n.c.
3 Blue VIN2 - supply voltage
4 Black RNG - range
5 Gray FE - functional earth, shield