Mounting
Leuze electronic MLC 520 33
6.3.2 MLC-PS protective screen
If there is a risk that the protective plastic screens of the safety sensors could get damaged, e.g. by welding
sparks, placing the additional, easy-to-replace MLC-PS protective screen in front of the safety sensors can
protect the device protective screen and considerably increase the availability of the safety sensor. Mount-
ing is performed using special clamp brackets, which are fastened on the lateral slot, via an Allen screw ac-
cessible from the front on each. The range of the safety sensor is reduced by approx.5%; when protective
screens are used on the transmitter and the receiver it is reduced by 10%. Mounting bracket sets with
2and 3clamp brackets are available.
NOTICE
If the length equals 1200mm or higher, 3clamp brackets are recommended.
Fig.6.13: MLC-PS protective screen fastened with MLC-2PSF clamp bracket