Technical data
Leuze electronic MLC 520 55
Fig.14.1: Dimensions of transmitter and receiver
Effective protective field heightH
PFE
goes beyond the dimensions of the optics area to the outer borders of
the circles labeled with R.
Calculation of the effective protective field height
H
PFE
[mm] = Effective protective field height
H
PFN
[mm] = Rated protective field height, this corresponds to the length of the yellow housing part (see ta-
bles below)
A [mm] = Total height
B [mm] = Additional dimensions for calculation of the effective protective field height (see table below)
C [mm] = Value for calculating the effective protective field height (see tables below)
Tab.14.7: Additional dimensions for calculating the effective protective field height
R=resolution B C
14mm 6mm 6mm
20mm 7mm 10mm
30mm 19mm 9mm
40mm 25mm 15mm
90mm 50mm 40mm
Tab.14.8: Dimensions (nominal protective field height), weight and response time
Device type Transmitter and receiver Receiver
Dimensions [mm] Weight [kg] Response time [ms] acc. to resolution
Model H
PFN
A 14mm 20mm 30mm 40mm 90mm
MLC…-150 150 216 0.30 5 4 3 3 -
MLC…-225 225 291 0.37 - 5 3 3 -
MLC…-300 300 366 0.45 8 7 4 4 -
MLC…-450 450 516 0.60 11 9 5 5 3