EasyManua.ls Logo

Leuze electronic SD4T 14 - Page 31

Leuze electronic SD4T 14
73 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation
Leuze electronic SOLID-4 31
TNT 35/7-24V
DEUTSCHENGLISHFRANÇAISITALIANOESPAÑOLNEDERLANDS
Beam heights with use of Safety Light Curtains for access guarding in accordance
with EN 999 and EN ISO 13857:
Table 6.1-1: Beam height
s above the reference plane and additional amount C for
access guarding applications
Calculation formula for safety distance S based on EN 999:
Calculation of the safety distance for a Safety Light Curtain with a resolution of up to 40
mm
, used for access guarding. The safety distance S is calculated as per EN 999
according to the formula:
Version Resolu-
tion
Lowest beam above
reference plane
Highest beam above
reference plane
Additional
amount C
(see formula)
SD4-14-hhhh 14 mm As per EN ISO 13857 As per EN ISO 13857 0 mm
SD4-20-hhhh 20 mm As per EN ISO 13857 As per EN ISO 13857 48 mm
SD4-30-hhhh 30 mm As per EN ISO 13857 As per EN ISO 13857 128 mm
SD4-40-hhhh 40 mm As per EN ISO 13857 As per EN ISO 13857 208 mm
SD4-90-hhhh 90 mm 300 mm 1200 mm 850 mm
S [mm] = K [mm/s] x T [s] + C [mm]
S = Safety distance in mm
K = Approach speed in mm/s
In the close area of 500 mm, 2,000 mm/s is used for the calculation. If the dis-
tance is greater than 500 mm, K = 1,600 mm/
s
can be used for the calculation.
In this case, however, a minimum of 500 mm applies for the safety distance.
T = Total delay time in seconds;
total from:
The response time of the protective device, t
AOPD
a)
The response time of the safety interface, if any, t
Safety interface
b)
The machine’s stopping time, t
Machine
c)
C = 8 x (d-14) in mm
Additional amount depending on the depth of penetration into the protective field
before t
urning on the AOPD
d = Resolution of AOPD up to a maximum of 40 mm
a) See Chapter 11.2
b) See technical data of the safety interface
c) See technical data of the machine or stopping time measurement
S [mm] = 2000 [mm/s] x (t
AOPD
+ t
Safety interface
+ t
Machine
) [s] + 8 x (d-14) [mm]

Table of Contents