Electrical connection
Leuze electronic SOLID-4 41
TNT 35/7-24V
DEUTSCHENGLISHFRANÇAISITALIANOESPAÑOLNEDERLANDS
7.1.3 Receiver SD4R
Notice!
When using an SD4R receiver, make certain to select transmission channel 1 on the
corr
esponding transmitter.
For the best-possible shielding, use connecting cabl
es on which the shield extends to the
knurled nut of the housing coupling (suitable cables are listed under accessories,
Chapter 12.4).
Fig. 7.1-3: SD4R 5-pin (view of
t
he pins)
Pin Color Assignment Function
1 Brown Supply voltage 24 V DC
2 White Output OSSD1, transistor switching output
3 Blue Supply voltage 0 V
4 Black Output OSSD2, transistor switching output
5 Gray Device internally
wired on
hous
i
ng
Functional earth
Mounting
plug housi
ng
Braided
shield
Shield Functional earth
Table 7.1-4: SD4R Receiver
connection assignment