6.2 Mounting notes
Special notes on mounting a SOLID-4 Safety Light Curtain for point of operation
guarding:
➢ Calculate the safety distance according to the formula in Chapt
er 6.1.1.
➢ Ensure that it is impossible to reach under, over,
around or walk behind the Safety Light
Curtain.
➢ Observe the maximum distance between machine table and protective field of 75 mm,
wit
h reference to a table height of 750 mm. If this is not possible because the safety
distance is too big, a mechanical barrier must be provided.
➢ Observe the minimum required distance to reflective surfaces.
a = Distance [mm]
b = Protective field width [m]
Fig. 6.1-5: Minimum distances from reflective surfaces as a function of the width of
the protective field