6.2 Mounting notes
Special notes on mounting a SOLID-4 Safety Light Curtain for point of operation
guarding:
Calculate the safety distance according to the formula in Chapt
er 6.1.1.
Ensure that it is impossible to reach under, over,
around or walk behind the Safety Light
Curtain.
Observe the maximum distance between machine table and protective field of 75 mm,
wit
h reference to a table height of 750 mm. If this is not possible because the safety
distance is too big, a mechanical barrier must be provided.
Observe the minimum required distance to reflective surfaces.
a = Distance [mm]
b = Protective field width [m]
Fig. 6.1-5: Minimum distances from reflective surfaces as a function of the width of
the protective field
130
b
a

Table of Contents