EasyManua.ls Logo

Leuze electronic SD4T 14 - 10 Troubleshooting; What Do I Do if an Error Occurs; Diagnostics; SD4 T Transmitter Diagnostic

Leuze electronic SD4T 14
73 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting
52 SOLID-4 Leuze electronic
DEUTSCH ENGLISH FRANÇAIS ITALIANO ESPAÑOL NEDERLANDS
10 Troubleshooting
The following information is used for rapid troubleshooting in the event of a malfunction.
10.1 What do I do if an error occurs?
If the AOPD shows an error on the display, the machine must be stopped immediately and
checked by an experienced technician. If it is determined that the error cannot be clearly
defined and remedied, your local Leuze office and or the Leuze electronic hotline can
assist.
10.2 Diagnostics
Operational malfunctions often have simple causes that you can remedy yourself. The
following tables will help you do this.
10.2.1 SD4T Transmitter diagnostic
10.2.2 SD4R-E Receiver diagnostics
The receiver displays faults and errors with Fxx codes. All possible codes and correspond-
ing activities are then performed.
Symptom Activity for removing errors
LED is not lit Check supply voltage
Check connecting cable
Replace transmitter if necessary
LED1 is lit red
c
ont
inuously
Hardware error, replace transmitter
LED2 is lit red
cont
inuously
Transmitter in test mode
Check test input, connect to 24 V DC
Table 10.2-1: T
r
ansmitter diagnostics
Code Cause/significance Activity for removing errors
LEDs and 7-segment displays are not lit 24 V DC supply voltage, check connect-
ing cable,
replace the receiver if necessary
F4 Internal hardware fault Send the device in
F6* Short circuit between ground and
OS
SD1 or cross circuit
Remove short circuit between ground,
overload or cross circuit; turn supply volt-
age off and on again
F7 OSSD short circuit after VCC or cross
circ
ui
t, output 1
Remove short circuit after VCC or cross
circuit; if it occurs again, send the device
in
F8* Short circuit between ground and
O
S
SD2 or cross circuit
Remove short circuit between ground,
overload or cross circuit; turn supply volt-
age off and on again
*) Locking error - a system reset is only achieved by switching the supply voltage off and on.

Table of Contents