Device parameters and interfaces Leuze electronic
44 BPS 8 Leuze electronic
8.1.3.2 Brief manual for the BPS Configuration Tool
General information
The BPS Configuration Tool program was developed as a convenient user-friendly tool to
operate all common Leuze BPS systems.
To install the tool, double click on the Setup.exe file and follow the instructions. After the
program has been successfully installed and started, the left side shows the standard project
Leuze electronic. In this project, every possible device has already been created.
This project is write-protected but can be edited arbitrarily and saved under a different name
using the Project -> Save as menu.
Creating a new project
!
Select Project -> New… or click on the symbol in the top left corner.
!
Assign a file name. Up to 256 characters are possible.
The .PCT extension must remain the same.
!
Assign a project name (= title) to the project. Up to 256 characters are possible.
!
Enter a description if required.
!
After confirmation with OK
,
the new project name is shown in the top left corner.
Create individual devices
!
Left click on project name (= title)
!
Device -> New -> Single device or click on the symbol in the top left corner.
!
Assign a device name
!
Select device type (only BPS can be selected).
!
Select BPS type
!
Select BPS version = software version of the device
!
After clicking OK
,
the new device is shown in the project.
Follow this procedure to create all devices required.
Notice!
When creating an individual device, the Leuze standard parameter set is always created to-
gether with the selected device according to the software version selected. The interface
data from the PC to the device are also created together with the Leuze standard settings.
These are: 9600 / 8 / 1 / None
Framing protocol: <STX><data><CR><LF>
Address: none