Device parameters and interfaces Leuze electronic
46 BPS 8 Leuze electronic
Terminal
The third option of communicating with the device is the terminal. This is only possible
online.
If no device is selected, only the terminal is available. Its interface settings are available
under Options -> Communication…. They can also be selected by clicking on the commu-
nication parameters displayed in the lower status bar.
Standard commands
The right third of the terminal window shows the following symbols for direct online
commands
Notice!
Please note that the device settings do not always displayed their current values if one
changes between online and offline programming. This means that if a parameter is edited
using an online command, the change is only displayed in the graphical menu (and thus
stored in the project) once the edited parameters have been uploaded from the device!
Terminal options
From the menu, select Terminal -> Options… or click on the symbol (terminal must be
selected). In the Send and Receive tabs select one of the 3 data formats ASCII, Hex and
Decimal. The standard format is ASCII.
Sets all parameters in the device to the factory settings!
Software reset
Version query
Displays the measurement values on the terminal
Does not display the measurement values on the terminal
Starts the measurement process
Stops the measurement process
User-defined commands