EasyManua.ls Logo

Levitronix PuraLev Console LCO-i100 - User Manual

Levitronix PuraLev Console LCO-i100
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
User Manual for LCO-i100 Console
www.levitronix.com
PL-4066-00, Rev05, DCO# 24-013
This document and its content are confidential and the property of Levitronix
®
and shall not be reproduced, distributed,
disclosed or used for manufacturing or sale of Levitronix
®
products without the expressed written consent of Levitronix
®
.
First Release: 09-Feb-2017
Last Update: 02-Feb-2024
PuraLev
®
Console
LCO-i100
PuraLev
®
i30SU/MU, PuraLev
®
i100SU/MU
PuraLev
®
i600SU
USER MANUAL
This manual contains information necessary for the safe and proper use of the PuraLev
®
LCO-i100
Console. Included are specifications for the standard configurations and instructions regarding its use,
installation, operation, adjustment, inspection and maintenance. For detailed description of the menu
structure and the configuration possibilities with the touch screen user interface the console software
manual PL-4067-00 can be consulted. For all in this manual revision described configurations and features
the console software LCO V1.09 R19 or higher is needed. For special configurations of the system refer to
accompanying information. Please familiarize yourself with the contents of the manual to ensure the safe
and effective use of this product. After reading this manual, please store the manual where the personnel
responsible for operating the pump system can readily refer to it at any time.
Question and Answer IconNeed help?

Do you have a question about the Levitronix PuraLev Console LCO-i100 and is the answer not in the manual?

Summary

Safety Precautions

General Safety Guidelines

Highlights general safety precautions and warnings for console usage.

Specifications

2.1 Specification of Console Components

Lists components, article numbers, characteristics, and values.

2.2 System Overview and General Specification

Describes system configurations and general specifications.

2.3 General Environmental Conditions

Details operating and storage environmental parameters.

2.4 Basic Dimensions of Console

Provides physical dimensions and mounting details of the console.

Engineering Information

3.1 IP Rating

Specifies the console's Ingress Protection rating.

3.2 Temperature Monitoring

Explains how the console manages temperature and prevents overheating.

Installation

4.1 Mechanical Installation

Covers desktop and wall-mounting procedures and specifications.

4.2 Electrical Installation

Details connection overview and interface specifications for electrical setup.

4.2.1 Connection Overview

Shows the various interfaces of the console and their designations.

4.2.2 PLC Interface

Details the pinout, description, and typical levels for the PLC connector.

4.2.3 Analog Input with 24 VDC Supply

Explains the connection and pinout for analog input with 24VDC supply.

4.2.4 General Installation Instructions

Provides essential steps and warnings for general installation procedures.

Operation

5.1 Basic System Operation

Covers essential operations like start-up, power-down, auto-resume, and software updates.

Maintenance

6.1 Cleaning

Details the procedure for cleaning the console housing safely.

Troubleshooting

Troubleshooting Overview

Explains how the console provides notifications for problems and failure mitigation.

Technical Support

Technical Support Contact

Provides contact information for Levitronix Technical Service Department.

Appendix

9.1 Regulatory Status

Details CE, UKCA, IECEE CB, NRTL/ETL certifications and WEEE disposal.

9.2 Symbols and Signal Words

Lists and explains various safety symbols and signal words used in the manual.

Summary

Safety Precautions

General Safety Guidelines

Highlights general safety precautions and warnings for console usage.

Specifications

2.1 Specification of Console Components

Lists components, article numbers, characteristics, and values.

2.2 System Overview and General Specification

Describes system configurations and general specifications.

2.3 General Environmental Conditions

Details operating and storage environmental parameters.

2.4 Basic Dimensions of Console

Provides physical dimensions and mounting details of the console.

Engineering Information

3.1 IP Rating

Specifies the console's Ingress Protection rating.

3.2 Temperature Monitoring

Explains how the console manages temperature and prevents overheating.

Installation

4.1 Mechanical Installation

Covers desktop and wall-mounting procedures and specifications.

4.2 Electrical Installation

Details connection overview and interface specifications for electrical setup.

4.2.1 Connection Overview

Shows the various interfaces of the console and their designations.

4.2.2 PLC Interface

Details the pinout, description, and typical levels for the PLC connector.

4.2.3 Analog Input with 24 VDC Supply

Explains the connection and pinout for analog input with 24VDC supply.

4.2.4 General Installation Instructions

Provides essential steps and warnings for general installation procedures.

Operation

5.1 Basic System Operation

Covers essential operations like start-up, power-down, auto-resume, and software updates.

Maintenance

6.1 Cleaning

Details the procedure for cleaning the console housing safely.

Troubleshooting

Troubleshooting Overview

Explains how the console provides notifications for problems and failure mitigation.

Technical Support

Technical Support Contact

Provides contact information for Levitronix Technical Service Department.

Appendix

9.1 Regulatory Status

Details CE, UKCA, IECEE CB, NRTL/ETL certifications and WEEE disposal.

9.2 Symbols and Signal Words

Lists and explains various safety symbols and signal words used in the manual.

Levitronix PuraLev Console LCO-i100 Specifications

General IconGeneral
BrandLevitronix
ModelPuraLev Console LCO-i100
CategoryWater Pump
LanguageEnglish

Related product manuals