EasyManua.ls Logo

Lexmark C734 - Page 48

Lexmark C734
436 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2-14 Service Manual
5026
84 <color> PC Unit
Missing
Scroll down the operator panel to see if the printer is showing that all four of the PC units
are missing. If so, check the HVPS cable between the system board and the HVPS.
Ensure that the cable is not plugged in backwards on the HVPS. Disconnect and
reconnect the cable to make sure there is good contact.
Insert or reinstall the specified photoconductor unit and see if problem clears. See
“Photoconductor unit removal” on page 4-118.
Remove the top access cover assembly (see “Top access cover assembly removal”
on page 4-40), and confirm that the camshaft follower (A) on the left side is not out of the
groove (B). If the camshaft follower is out of the groove, raise the arm, use a screwdriver
to ease the camshaft follower back into the groove. You need to press down to snap it
into position.
Check the high voltage contacts path, especially the “finger” on the specified
photoconductor unit (printer is shown with components removed for clarity).
If the contacts are good, replace the HVPS. See High-voltage power supply (HVPS)
removal” on page 4-94.
If the problem persists, replace the system board. See “System board removal” on
page 4-139.
84 <color> PC Unit Near
Life Warning
Select Ignore to clear the message and continue printing.
Order the specified photoconductor unit. When print quality is reduced, install the new
specified photoconductor unit using the instruction sheet that comes with the replacement
specified photoconductor unit.
If the problem persists, replace the system board. See “System board removal” on
page 4-139.
Error code Action
AB
High voltage
contact path
High voltage
power supply
Finger

Table of Contents

Related product manuals