3
MULTI Standard
General information
2. Nomenclature
2.1 Indoor Units
2.2 Outdoor Units
Model Name AMN Q 12 G S J A A
No. 1 2 3 4 5 6 7 8
No. Signification
1
A*N : Indoor units using R410A
* Indicates Product type
M : Multi Room Air conditioner
2
Model type
Q : DC Inverter Cooling Only
3
Nominal Capacity
Ex) 9,000 Btu/h Class → '09', 18,000 Btu/h Class → '18'
4
Electrical rating
G: 1Ø, 220-240V, 50 Hz / 1Ø, 220V, 60 Hz
5,6
Indoor unit type
Chassis name
7
Functions
A : Basic (Standard)
8
Serial number
Model Name A2U Q 18 G F A B
No.
1 2 3 4 5 6 7
No. Signification
1
Indicates that this is multi system outdoor unit using R410A
Ex) A2U : Connectable max. 2 indoor units
A3U : Connectable max. 3 indoor units
2
Model type
Q : DC inverter Cooling Only
3
Cooling/heating capacity
Ex) 18,000 Btu/h Class → '18', 24,000 Btu/h Class → '24'
4
Electrical rating
G : 220-240V, 1Ø, 50Hz / 220V, 1Ø, 60Hz
L : 380-415V, 3Ø, 50Hz / 380V, 3Ø, 60Hz
5
Outdoor unit type
F : Fixed multi type
6
Functions
A : Basic (Standard)
7
Serial number