195
ENGLISH
194
INSTALLER’S SETTING OPTIONS INSTALLER’S SETTING OPTIONS
h Fan speed fixed setting value
- 01: variable
- 02: fixed
Press and hold ‘wireless remote controller signal receiver part’ of the remote controller for 3
seconds or longer to enter the installer function.
At the Code field select fan speed fixed setting code value ‘11’.
- You can press ‘’, ‘’ button to change the code value.
At the Value 1 field, press the ‘’, ‘’ button to select wind amount fixing setting value, and
then press ‘Done’ button to complete the fan speed fixing setting.
- If you do not press ‘Done’ button, your changes will not be applied.
Fan speed fixing (air conditioner / DX type ventilator)
It is the function to apply different fan speeds automatically for each thermal control status.
h Variable: When COMP is ON, operate as the set fan speed, and when COMP is OFF, operate
at ‘ROW’ fan speed.
Fixed: When COMP is ON, operate as the set fan speed, and when COMP is OFF, also oper-
ate at the set fan speed.
Celsius / Fahrenheit Switching (air conditioner)
This function is used for switching the display between Celsius and Fahrenheit.(Optimized only
for U.S.A)
Press and hold ‘wireless remote controller signal receiver part’ of the remote controller for
3seconds or longer to enter the installer function.
Select remote controller Celsius / Fahrenheit Switching code value ‘12’.
- You can press ‘’, ‘’ button to change the code value.
In value1, use ‘’, ‘’ button to select Celsius control unit setting value, and press ‘Done’
button to complete the Celsius / Fahrenheit Switching setting.
- If you do not press ‘Done’ button, the setting value will not be applied.
h Celsius control unit setting value
- 000: Celsius
- 001: Fahrenjeit
h If there is no button input for about 60 seconds after the setting, it automatically exits from the
setting mode.
h If no buttons are pressed for about 60 seconds after the setting, it automatically exits from the
setting mode.