Liebert
®
GXT4
UPS 230V 700VA-3000VA
User Manual

Table of Contents

Other manuals for Liebert GXT4

Questions and Answers

  • W
    William JohnsonJul 26, 2025
    What to do if the Liebert UPS battery indicator is illuminated?
    • M
      Michelle HaleJul 27, 2025
      If the battery indicator is illuminated on your Liebert UPS, it means the unit is running on battery power. This can happen for a few reasons: * The UPS might not be securely plugged into the wall. Make sure it's properly connected. * The UPS input protection fuse may have blown. If this is the case, save your work, close any open applications, replace the fuse, and restart the UPS. * The mains power might be out of the acceptable range. Save your data and close applications, then verify that the mains supply voltage is within the correct limits for the UPS.
  • B
    Brian SimonAug 1, 2025
    Why does my Liebert UPS have reduced battery backup time?
    • J
      Julie RushAug 1, 2025
      Reduced battery backup time on your Liebert UPS can stem from several causes: * The batteries may not be fully charged. To resolve this, keep the UPS plugged in continuously for at least 24 hours to allow the batteries to recharge. * The UPS might be overloaded. Check the load level indicator and reduce the load on the UPS if necessary. * The batteries may be old and unable to hold a full charge. If this is the case, replace the batteries. Contact your local dealer, Emerson representative, or Emerson Channel Support for a replacement battery kit.
  • R
    Rachel WardAug 8, 2025
    What does it mean when the Liebert GXT4 UPS battery indicator is flashing?
    • S
      Shelby CarlsonAug 8, 2025
      A flashing battery indicator on your Liebert UPS indicates that the battery source is unavailable and may be accompanied by a continuous horn. Check the battery connections, then completely power down and restart the UPS. Note that if the battery circuit opens while the UPS is running, it will be detected during the next battery test.
  • J
    Jessica FergusonAug 13, 2025
    What to do if Liebert UPS fails to start?
    • D
      David HernandezAug 13, 2025
      If your Liebert UPS fails to start, here are a couple of things to check: * The UPS may be short-circuited or overloaded. Ensure the UPS is off, disconnect all loads, and check the output receptacles for obstructions. Also, make sure the connected loads aren't defective or shorted internally. * The batteries may not be sufficiently charged or properly connected. Check the internal battery connection and connect it if necessary. If the battery is connected, allow the UPS to charge for 24 hours by connecting it to input power, then try starting it again.
  • J
    Justin BryantAug 19, 2025
    Why is the bypass indicator flashing on my Liebert GXT4?
    • J
      jasmine50Aug 19, 2025
      The bypass indicator on your Liebert UPS flashes when the voltage or frequency of the AC input is outside acceptable limits, disabling the bypass. The AC input powers the PFC input and serves as the bypass source. If the AC is present but the voltage or frequency exceeds the acceptable range for safe operation with a load, the bypass will be disabled, and this indicator will flash, indicating that the bypass is unavailable.

Summary

IMPORTANT SAFETY PRECAUTIONS

PRODUCT DESCRIPTION

Operating Mode

Details the different operational states of the UPS.

Battery Mode

Describes operation when utility power fails.

INSTALLATION

Preparation for Installation

Pre-installation steps and environmental considerations.

Mechanical Installation

Instructions for physically mounting the UPS.

Cable Connection

How to connect power and communication cables.

Connecting to AC Mains and Loads

Steps for connecting the UPS to power sources and equipment.

OPERATION AND DISPLAY PANEL

Menu Navigation and Status Screens

Explores the UPS menu system, including status, configuration, and logs.

Fault List

Lists UPS fault messages and recommended corrective actions.

OPERATION

Starting the UPS

Step-by-step guide to powering on the UPS.

Shut Down the Liebert GXT4

Procedures for safely powering down the UPS.

COMMUNICATION

Configuration Program

Using software to configure UPS settings.

MAINTENANCE

Replacing the Internal Battery Pack

Guide for safely replacing the UPS internal battery.

Precautions

Important safety precautions during UPS operation and maintenance.

TROUBLESHOOTING

UPS Symptoms

Indicators that the UPS may be malfunctioning.

Troubleshooting

A guide to diagnosing and resolving UPS problems.

Liebert GXT4 Specifications

General IconGeneral
Form FactorTower/Rack Mount
Power Factor0.9
Battery TypeSealed Lead-Acid (SLA)
Backup TimeVaries by model and load
Waveform TypeSinewave
Communication PortsUSB, RS-232
TopologyOn-line Double Conversion
Output Frequency50/60 Hz +/- 0.1 Hz
Typical Recharge Time3 hours to 90%
Operating Temperature0°C to 40°C (32°F to 104°F)
Storage Temperature-15°C to 45°C (5°F to 113°F)
Humidity0-95% non-condensing
DimensionsVaries by model
WeightVaries by model
CertificationsUL, cUL, CE, RoHS
Output Voltage208/220/230/240VAC