Installation
Liebert
®
GXT4
10
2.0 INSTALLATION
2.1 Unpacking and Inspection
Unpack the UPS and conduct the following checks:
Inspect the UPS for shipping damage. If any shipping damage is found, report it to the carrier and
your local dealer or Emerson
®
representative immediately.
Check the accessories against the delivery list. If there is any discrepancy, contact your local
dealer or your Emerson representative immediately.
2.2 What’s Included
Terminal Block Communication Terminals
Compact Disk with:
Liebert MultiLink
®
Shutdown Software
Configuration Program
User Manual
USB Cable—one, 1.2m (3.9 ft.) long
RS-232 Cable—one, 2m (6-1/2 ft) long
Cable Strain Relief—two pieces
Rack mounting hardware, including screws, handles and mounting rail kit (not included with “E”
models)
Plastic tower stand sets—two (four pieces)
Warnings, Safety Instructions booklet and WEEE recycling sheet (ISO 14001 compliance)
With 700VA - 1500VA Units:
10A IEC C13 C14 Output Cable—two, 2m (6-1/2 ft.) long
CEE 7/7 (Schuko) to IEC C13 input cord—one, 2.5m (8-1/2 ft.) long (not included with “E” models)
BS 1363 (UK) to IEC C13 input cord—one, 2.5m (8-1/2 ft.) long (not included with E models)
Australian type A to SAA input cord—one (except “E” models)
With 2000VA - 3000VA Units:
10A IEC C13 C14 Output Cable—three, 2m (6-1/2 ft.) long
CEE 7/7 (Schuko) to IEC C20 Input Cable—one, 2.5m (8-1/5 ft.) long (not included with “E”
models)
BS1363 (UK) to IEC C20 Input Cable—one, 2.5m (8-1/5 ft.) long (not included with “E” models)
Australian type A to SAA input cord—one (not included with “E” models)
2.3 Preparation for Installation
2.3.1 Installation Environment
Install the UPS indoors in a controlled environment where it cannot be accidentally turned Off.
The installation environment should meet the specifications in 9.0 - Specifications.
Place the UPS in an area where airflow around the unit is unrestricted and away from water,
flammable liquids, gases, corrosives and conductive contaminants. Avoid direct sunlight.
NOTE
The GXT4 External Battery Cabinet shipping package includes one battery cabinet, two spacers
for tower configuration and one DC power cable and rack mounting hardware, including
screws, handles and mounting rail kit (not included with “E”) models.
NOTE
Operating the Liebert GXT4 in temperatures above 25°C (77°F) reduces battery life.

Table of Contents

Other manuals for Liebert GXT4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Liebert GXT4 and is the answer not in the manual?

Liebert GXT4 Specifications

General IconGeneral
Form FactorTower/Rack Mount
Power Factor0.9
Battery TypeSealed Lead-Acid (SLA)
Backup TimeVaries by model and load
Waveform TypeSinewave
Communication PortsUSB, RS-232
TopologyOn-line Double Conversion
Output Frequency50/60 Hz +/- 0.1 Hz
Typical Recharge Time3 hours to 90%
Operating Temperature0°C to 40°C (32°F to 104°F)
Storage Temperature-15°C to 45°C (5°F to 113°F)
Humidity0-95% non-condensing
DimensionsVaries by model
WeightVaries by model
CertificationsUL, cUL, CE, RoHS
Output Voltage208/220/230/240VAC