Operator Control and Display Panel
10
2.9 Language Selection
The LCD menus and data display is available in
12 languages. To select a different language:
From the main menu, press the F1 (shift) key
to move the cursor to the menu at the top of
the screen.
Press F2 and F3 (left and right arrows) as
needed to select the Language menu.
Press F1 (shift) to move the cursor to the data
and settings area of the LCD.
•Use F2 and F3 (up and down) to select the
required language.
Press the F4 (enter) key to accept the language
selection.
Return to the main menu by repeatedly press-
ing F1 (ESC) as needed; all text on the LCD
will now be displayed in the selected language.
2.10 Current Date and Time
To change the system date and time:
From the main menu, press the F1 (shift) key
to move the cursor to the menu at the top of
the screen.
Press F2 and F3 (left and right arrows) as
needed to select the Settings menu.
Press F1 (shift) to move the cursor to the data
and settings area of the LCD.
•Use F2 and F3 (up and down) to select the
Date & Time option, then press F4 (enter).
Position the cursor on the row in which the
date and time are displayed, then press
F4 (enter).
•Using the F2 and F3 (up and down) keys,
enter the current time and date information.
Press F4 (enter) to save the settings, then
press F1 (ESC) to return to the main menu.
?
F2 F4
HELP
F1 F3
RecordsBattery Language
ENGLISH DEUTSCH
POLSKI FRANCAIS ITALIANO
ESPAÑOL NEDERLANDS SVENSKA
РУССКИЙ PORTUGUÊS
2004-01-22 12:30:36Liebert NXb
Single Normal30kVA-3X3
Fault reset 01-22 10:32
Manual turn on 01-22 10:32
Normal mode 01-22 11:05
?
F2 F4
HELP
F1 F3
LanguageRecords Settings
Display contrast
Date format set M/D/Y
D/M/Y M/D/Y Y/M/D
Date & time
01-22-2004 12:30:36
2004-01-22 12:30:36Liebert NXb
Single Normal30kVA-3X3
Fault reset 01-22 10:32
Manual turn on 01-22 10:32
Normal mode 01-22 11:05

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Liebert NX series and is the answer not in the manual?

Liebert NX series Specifications

General IconGeneral
Frequency50/60 Hz
DisplayLCD
TopologyDouble Conversion
Input Voltage208/220 VAC
Output Voltage208/220 VAC
CommunicationSNMP
Operating Temperature0 to 40°C
Battery TypeVRLA
Humidity0 to 95% (non-condensing)
DimensionsVaries by model. See product documentation.
WeightVaries by model. See product documentation.
Storage Temperature-15-50°C (5-122°F)