Do you have a question about the Liebert NXC 40kVA and is the answer not in the manual?
Power Rating | 40 kVA |
---|---|
Real Power | 36 kW |
Input Frequency | 50/60 Hz |
Output Frequency | 50/60 Hz |
Operating Temperature | 0°C to 40°C |
Topology | Double Conversion Online |
Input Voltage | 400V |
Output Voltage | 400V |
Phase | 3-phase |
Battery Type | Valve-regulated lead acid (VRLA) |
Battery Backup Time | Varies depending on load |
Efficiency | Up to 96% |
Describes UPS features, design concepts, system design, and parallel system.
Details the various operation modes of the UPS, including Normal, Battery, ECO, and Bypass.
Covers battery management functions, protection, and temperature compensation.
Provides safety precautions, transportation, unpacking, and initial inspection guidelines.
Details requirements for UPS and battery location, storage, and environmental conditions.
Covers cabinet moving, clearance, cable access, and final positioning and fixing.
Guides on wiring power cables, including input, output, battery, ground, and protective devices.
Details on wiring various signal cables, communication ports, and EPO connections.
Overview of the control panel, including LCD, LEDs, keys, and audible alarms.
Describes the LCD screen types, start screen, primary screen, and default screen.
Details menu items, prompt windows, and the UPS alarm list for operation.
Provides an overview of UPS operations and essential safety precautions.
Step-by-step guides for starting the UPS in Normal, ECO, and Battery modes.
Details procedures for transferring between Normal, Battery, Bypass, and Maintenance modes.
Explains how to perform battery and UPS self-tests.
Guides for completely powering down the UPS and shutting down while maintaining load power.
Covers EPO procedures, reset after EPO, and automatic restart functionality.
Instructions for selecting language, changing date/time, and managing control passwords.
Overview of battery components, safety precautions, and battery types.
Covers battery installation environment, number of batteries, and battery room design.
Details battery protection features like BCB and procedures for battery installation and connection.
Information on the optional BCB box, its reference current, and battery maintenance.
Guidelines for the proper disposal of used lead-acid batteries.
Covers general information, installation procedures, checks, cables, and remote EPO for parallel systems.
Details startup, maintenance bypass, isolation, reintegration, and shutdown procedures for parallel systems.
Explains cabinet installation, protective devices, power cables, and LBS cables for LBS systems.
Lists available UPS options and provides an introduction to their operation.
Covers installation and configuration for various options like inductors, battery kits, sensors, and cards.
Describes SNMP and Modbus protocol communications for UPS monitoring and management.
Explains communication via IS-Relay card and dry contact ports for status monitoring.
Highlights safety for servicing and details service life of key UPS components.
Provides procedures for fuse replacement and general UPS and options maintenance.
Lists conformance standards, environmental characteristics, and mechanical specifications.
Details electrical specifications for input rectifier, DC circuit, inverter output, and bypass input.
Presents data on UPS efficiency and power loss across different load conditions.