Max. angle of movement:
Note: To ensure operation the Quick Release must be rotated
45
o
C (max.) due to tolerance/load variation. Some units may
operate before 45
o
C is reached.
To avoid damaging the QR, it should not go above 45
o
C.
Drawing no.: 031944
Recommendations
The release cable has to be provided by the customer.
The design of the release cable has to be as specified.
It is important to observe the max. active (the moving part of the cable) cable length of 12 mm.
Do not pull more than this length otherwise the QR will be damaged!
The force required to operate the Quick Release is approx. 5 kg.
When more than the recommended 5 kg force is used to activate the QR, more friction will be created in the internal actuator/QR mechanism.
This means that a greater load will be required to ensure successful operation.
The QR cover is supplied attached to the actuator but not mounted.
LA31 with external quick release, types I, K, L, and M can maximum pull 200 N.
The necessary release force on an actuator with 5 mm pitch is 75 kg for 6 mm pitch = 50 kg.
It is not possible to combine splines with the external quick release.
LA31 with quick release is always with brake (push).
The flexible back fixtures (05 or 06) must be standard when the LA31 is equipped with quick release.
LA31 with brake. An LA31 brake in a push application brakes actively when the actuator moves in an inward direction. The same applies to an
actuator mounted with a brake in a pull direction. It brakes in an outward direction. Under this condition the standard motor uses up to 4 Amp.
and the fast motor uses up to 6 Amp. (Measured after 5 cycles at normal room temperature).
Therefore if the LA31 with brake is used together with a CB7 it is important that the current cut-off limit of the control box is higher than the used
Amp. i.e. not lower than 4 Amp.
LA31 with brake cannot be combined with CB9/CB7 with emergency lowering. For all LA31 actuators with brake self-locking ability up to max.
load it is only possible in one direction: push or pull.
The LA31 actuator must not be exposed to more than 4000 N in pull. In applications where misalignments may occur the normal back fixture can
take max. 1500 N in pull whereas the flexible back fixture can take up to 4000 N in pull.
The actuator must be mounted at right angles (90
o
C) to it is fixing/load (max.1.5
o
C deviation)
LA31 actuators with protection class IPX6 must be mounted with the screw holes mounted facing downwards. To ensure that any water remaining
from cleaning / washing is not collected in the screw holes.
Not OK
OK
OK
Correct mounting: