LED indicators
System status
CAL40+
PRIORITY LED4 + LED5 LED state
(Not listed = off)
States in normal
use
Comments Reset Buzzer
0
LED 4
flashing according to
BLE pairing state
Pairing BLE
Not ready to
operate
Wait until ready
Buzzer in
accordance with
BLE pairing state
1
LED 4 + 5
constantly on (only
when key is pressed)
Emergency stop
activated
Not ready to
operate
Release emergen-
cy stop button -
2
LED 4 + 5
flashing fast (synchro-
nous)
FATAL ERROR
Cannot operate,
has to be reset
No movement
possible
Reset fatal error
routine
Buzzer on key
press
3
LED 5
constantly on
SWL active
4
LED 5
flashing
SWL confirmation
Buzzer in
accordance with
learn function
5
LED 5
flashing slowly
Overload on CH1
Overload state
kept for 10 sec.
Momentary not
ready to lift.
Reduce load
Beeps twice
6
LED 4
flashing slowly
Duty cycle guard
Momentary not
ready to lift
Wait until ready -
7
LED 4
constantly on
Service needed
Operation is
possible
SDT, App, HB -