5 Servicing
Inspection and maintenance every 500 to 1000 operating hours or once a year
Tighten lift mast fastening
E335/095
¾ Lift fork carriage and secure from accidental
sinking.
1
1
e3861314
¾ Check secure positi
oning of fastening
screws (1) (4 per sid
e) of bearing half-sec-
tions for lift mast b
earing and tighten as
necessary.
Tightening torque: 80 Nm
Check pedals and linkage and oil
¾ Remove rubber mat from floor plate.
¾ Remove floor plate.
¾ Check bolt and joint securing devices for
secure positioning.
¾ Lightly oil rod bearings and fork cleves as
necessary.