EasyManua.ls Logo

Linde E18 - Fuses for special equipment

Linde E18
222 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Servicing 5
Inspection and maintenance every 3000 operating hours or every 2 years
Check the condition and secure po-
sitioning of electric cables, cable
connectors and connections
NOTE
Oxidised connections and brit
tle cables result
in voltage drops , so causing
malfunctions.
e3861394
¾ Remove the screws from the floor plate
fastening (pedals) and lift up floor plate.
¾ Check all electric cables and connections
on contactor support.
¾ Cable connections on electri
c motors:
check plug connections for s
ecure posi-
tioning and oxidation resid
ues.
¾ Check battery cables for secure positioning.
¾ Check electric wiring for abrasion and se-
cure positioning.
¾ Check earth wire for secure pos
itioning.
¾ Remove oxidised connections and replace
brittle cables.
Operating Instructions 386 807 1001 EN 03/2006 125