Rev:11.08.19 Page 71 CCD-0001573-08
Error Display Screen - OneControl Touch Panel/App.
NOTE: Errors can only be cleared via the OneControl Touch Panel (Fig. 4) or the OneControl App. The only
exception is when the Auto Leveling Control Touch Pad (Fig. 3) was used to abort an auto sequence.
In this case, the error can be cleared by pressing any Auto Leveling control button. Correct Error to
clear it, then press "OK." If Error persists, message will continue to display.
LCD Message What Is Happening? What Should Be Done?
"EXCESS ANGLE"
Unsecured sensor. Check and secure sensor placement.
Uneven or sloped site. Relocate the trailer.
"EXCESSIVE ANGLE"
Sensor not properly secured. Check and secure sensor placement.
Excessive angle reached during
manual operation.
Relocate the trailer.
"BAD CALIBRATION"
Trailer Zero Point was not set
correctly.
Reset Zero Point. See "Zero Point
Calibration" section.
"FEATURE DISABLED"
Hitch recognition requested but no
hitch height set.
Perform "AUTO LEVEL" sequence to
establish hitch height.
Zero Point not set.
Set Zero Point. See "Zero Point Calibration"
section.
"LOW VOLTAGE"
Bad connection or wiring.
Check wiring - repair or replace.
Discharged or bad battery.
Test battery voltage under load - charge or
replace.
"OUT OF STROKE"
Unsecured controller. Check and secure controller placement.
Uneven or sloped site. Relocate the trailer.
"EXTERNAL SENSOR" Bad connection or wiring.
Replace or repair connection to rear remote
sensor.
"JACK TIME OUT"
System could not level in expected
time.
Check for obstructions, leaks, fluid level and
voltage to power unit motor under load.
"AUTO LEVEL FAILURE"
Unsecured controller. Check and secure controller placement.
Voltage drop.
Test battery voltage under load - charge or
replace.
"FUNCTION ABORTED"
User has aborted an automatic
leveling sequence.
Restart the sequence.
"HALL POWER SHORT"
Short circuit detected on one or more
of the 5K jack power lines.
Check harness and replace or repair.
“CAN’T COMPLETE
LEVEL IN THIS
LOCATION. PLEASE
RELOCATE RV TO
FLATTER TERRAIN”
The trailer is parked on a steep incline
during auto level. The front cannot
be leveled and the front jacks are
already fully retracted.
Relocate the trailer.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lippert Components PSX2 and is the answer not in the manual?

Lippert Components PSX2 Specifications

General IconGeneral
BrandLippert Components
ModelPSX2
CategoryLifting Systems
LanguageEnglish

Related product manuals