Rev: 12.28.22 Page 27 CCD-0004051
Setting the ACS Stop Procedure
Setting the UP Position
1. Make sure the safety belts are unfastened.
2. Turn the key switch to the ON position (Fig. 59B) located on the key switch.
3. Press and hold the UP arrow-shaped button (Fig. 59C) on the key switch. The bed will keep moving
until you reach the pre-set stop position.
4. If the Smart Bed Lift stops too low, turn the white screw (Fig. 53A) in the ACS module counterclockwise.
This will allow the Smart Bed Lift to move higher. If the Smart Bed Lift stops too high, turn the white
screw (Fig. 53A) clockwise until the Smart Bed Lift stops lower.
NOTE: One full rotation of the screw is approximately one inch of movement up or down.
5. Press the UP arrow (Fig. 59C) and DOWN arrow (Fig. 59D) to run the Smart Bed Lift system after each
adjustment of the screw. If necessary, repeat this procedure until desired stop location is obtained.
Setting the DOWN Position
1. Make sure the safety belts are unfastened.
2. Turn the key switch to the ON position (Fig. 59B) located on the key switch.
3. Press and hold the DOWN arrow-shaped button (Fig. 59C) on the key switch. The bed will keep moving
until you reach the pre-set stop position.
4. If the Smart Bed Lift stops too high, turn the yellow screw (Fig. 53B) counterclockwise. This will allow
the Smart Bed Lift to move lower. If the Smart Bed Lift stops too low, turn the yellow screw (Fig. 53B)
clockwise until the Smart Bed Lift stops higher.
NOTE: One full rotation of the screw is approximately one inch of movement up or down.
5. Press the UP arrow (Fig. 59C) and DOWN arrow (Fig. 59D) to run the Smart Bed Lift system after each
adjustment of the screw. If necessary, repeat this procedure until desired stop location is obtained.
A
B
Fig. 53