LNS Alpha 538 - Alarm Code: Booster Failure During Extraction (AL33)

LNS Alpha 538
115 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CHAPTER 9: MALFUNCTIONS 9-12
ALPHA 538/552
AL33: Booster failure during extraction!
Description
This alarm is generated if the signal (X25 –
SQ16) is not detected after the bar has been
extracted from the collet of the bar feed. Before
the guiding channel opens to load a new bar, the
remnant check device confirms that the remnant
has been extracted from the collet of the bar
feed.
Solutions
Check the function of bar stock clamping and
clamping jaws.
Check function and adjustment of SQ16.
Contact LNS SA. for further information.
AL34:
Left empty
AL35:
Left empty
AL36:
Left empty
AL37:
Left empty